11
Mounting
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
Description of the hood
Fig. 1
H. Interconnection cable
K. Control lever
Attention! The control lever is already supplied. It is to
be installed last, before connecting the hood to the
mains.
Insert the control lever into the apposite housing (see
drawings on the first pages of this booklet - triggered
connection, compulsory direction.
L. Halogen bulb
M. Lateral filter holder frame
N. Active carbon filter
O. Metal anti-fat filter
P. Anti-fat and carbon filters holder frame
Q. Filter holder frame releases
Operation
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
The hood is equipped with a “TOUCH SENSOR” device able
to determine the control of the lights and the speed when the
user touches the control bar. Read the instructions below
carefully for this purpose.
The cooker hood can be controlled through a remote control
available as accessory kit (see the paragraph relating to the
functioning of the remote control).
Automatic switch-on function
The hood is equipped with a temperature sensor that starts
the motor at the 1st suction speed (power) when the room
temperature around the hood is higher than 70°C.
The user can, however, switch off or modify the suction speed
(power). (See paragraph “Control of suction speed (power))”.
Control of suction speed (power)
The selection of the suction speed (power) is cyclical,
according to the speed sequences “”stand-by - 1-2-3-4- Stand
by -1-2-”… so that at every touch of the UPPER PART of the
control bar the suction speed (power) increases by a level
and then to switches off (stand-by) if the control bar is touched
again when the hood is at suction speed (power) 4.
It is possible lo turn the hood off (standby) even when the
hood is at any speed by pressing the UPPER PART of the
control bar (for more than 3 seconds).
It is possible to determine what suction speed (power) the
hood is in when the bar is equipped with a led that changes
colour on the basis of the suction speed (power), as follows:
Hood in stand-by: LED OFF
1st suction speed (power) - led GREEN
2st suction speed (power) - led ORANGE (amber)
3st suction speed (power) - led RED
4st suction speed (power) - led RED (FLASHING)
Note: the 4
th
aspiration speed (power) remains on for 5
minutes after which the aspiration motor positions itself on the
2
nd
speed.
Touched once more, the suction motor switches off (Stand-
by).
Need to wash the anti-fat filter: GREEN led FLASHING
(read the instructions relative to “Reset and configuration of
the filters saturation signal")
Need to wash or replace the carbon filters: ORANGE
(amber) led FLASHING (read the instructions relative to
“Reset and configuration of the filters saturation signal”)
Note: reset can be carried out both with the control lever and
the remote control.
Control of the central light
The central light can be switched on and off by touching the
LOWER PART of the control bar BRIEFLY.
Control of the lateral lights (when envisaged)
The lateral lights can be switched on and off by touching IN A
PROLONGED MANNER the LOWER PART of the control
lever.
The PROLONGED TOUCH allows, other than switching on
and off, adjusting the intensity of the light emitted by the lamp.
Note: The functions of switching and off (and adjustment)
alternate.
The light intensity regulation feature is not available for hoods
with neon lights.
Reset and configuration of the filters saturation signal
Switch the hood on at any speed (see paragraph above
“Selection of the suction speed (power)”
Reset anti-fat filter saturation signal (GREEN LED
FLASHING on the control level)
First proceed with the maintenance of the filter as
described in the corresponding paragraph.
Touch in a prolonged manner (more than 3 seconds) the
UPPER PART of the control lever, the LED stops flashing to
indicate that the reset of the signal has been carried out and
the hood switches off.
Reset anti-fat filter saturation signal ORANGE (amber)
LED FLASHING
First proceed with the maintenance of the filter as
described in the corresponding paragraph.
Touch in a prolonged manner (more than 3 seconds) the
UPPER PART of the control lever, the LED stops flashing to
indicate that the reset of the signal has been carried out and
the hood switches off.